IBM DataPower Operations Dashboard v1.0.14.0
A newer version of this product documentation is available.
You are viewing an older version. View latest at IBM DPOD Documentation.
Cannot Add a Gateway because of System Identifier Mismatch
Symptoms
Attempting to add a new gateway to DPOD results in the following error message:
The device's system identifier does not equal to <Gateway Name>However, the system identifier (appliance name) is exactly the same as the name provided in DPOD for that gateway when trying to add it.
Cause
The gateway user provided to DPOD cannot make SOMA requests to the gateway, and DPOD fails to read the real system identifier (appliance name) of the gateway.
See Prepare your Monitored Devices for more information.
Resolution
First make sure the system identifier (appliance name) in the gateway's Web GUI is exactly the same as provided to DPOD when adding the gateway.
Make sure the user is privileged in the gateway's Web GUI.
Try to login to the gateway's Web GUI with the privileged user and reset its password if indeed it expired.