IBM DataPower Operations Dashboard v1.0.12.0
A newer version of this product documentation is available.
You are viewing an older version. View latest at https://ibm.biz/dpod-docs.
Firmware Upgrade Status Codes
Here are some common statuses for Firmware upgrade task executions.
Status Code | Description |
|---|---|
WAITING_FOR_PRE_VALIDATION | The task was entered into the execution queue, it was not yet validated or checked, and eventually may not get executed |
SKIPPED_DEVICE_DOES_NOT_EXIST | The task will not execute - the device was not available or does not exist/setup in DPOD |
SKIPPED_NO_DEVICES_MATCHING_PATTERN | The task will not execute - no devices were matching the device pattern requested in the activity |
VALIDATION_INTERNAL_EXCEPTION | The task will not execute - an internal error occurred, a UUID will be printed, search the logs for this UUID in order to get more information |
ERROR_IMAGE_FILE_DOES_NOT_EXIST | The task will not execute - The firmware image file that was specified for the activity was not found on disk |
ERROR_UNSUPPORTED_DEVICE_TYPE | The task will not execute - The only supported device types are IDG, XB62, XI52 and XG45 |
ERROR_COULD_NOT_PARSE_IMAGE_FILE_NAME | The task will not execute - the image file's name was not in the standard format: |
ERROR_DEVICE_AND_IMAGE_MODEL_GROUPS_ARE_DIFFERENT | The task will not execute - the image file's prefix indicated a model type different than the device type, |
ERROR_DOWNGRADE_NOT_SUPPORTED | The task will not execute - the firmware version of the image file was lower than the device's firmware version. |
ERROR_DOWNGRADE_MAJOR_RELEASE_NOT_APPROVED | The task will not execute - the firmware version of the image file was lower than the device's version, but in the same major version (e.g. 7.5.1.7 to 7.5.1.4), |
ERROR_DEVICE_AND_IMAGE_VERSIONS_ARE_IDENTICAL | The task will not execute - the firmware version of the image file was identical to the device's version. |
ERROR_DEVICE_FEATURES_NOT_FOUND_IN_IMAGE | The task will not execute - the image file does not contain features (Tibco-EMS or DCO-Oracle) that found on the device |
ERROR_IMAGE_FEATURES_NOT_FOUND_IN_DEVICE | The task will not execute - the device does not contain features (Tibco-EMS or DCO-Oracle) that found in the image file |
ERROR_UNKNOWN_IMAGE_FILE_FORMAT | The task will not execute - only image files that end with scrypt3 or scrypt4 are supported |
ERROR_IMAGE_NOT_DESIGNED_FOR_VIRTUAL_DEVICES | The task will not execute - scrypt3 file was chosen for upgrading virtual appliance |
ERROR_IMAGE_NOT_DESIGNED_FOR_PHYSICAL_DEVICES | The task will not execute - scrypt4 file was chosen for upgrading physical appliance |
ERROR_NOT_ENOUGH_FREE_ENCRYPTED_SPACE_ON_DEVICE | The task will not execute - there is not enough free space to upload the image file to the device's encrypted file system (free space is needed in both encrypted and temporary file systems) |
ERROR_NOT_ENOUGH_FREE_TEMP_SPACE_ON_DEVICE | The task will not execute - there is not enough free space to upload the image file to the device's temporary file system (free space is needed in both encrypted and temporary file systems) |
ERROR_FOUND_UNSAVED_CHANGES_ON_DEVICE | The task will not execute - Unsaved changes were found in the device, apply all unsaved changes before starting the firmware upgrade again. |
SKIPPED_BECAUSE_ERROR_POLICY | The task will not execute - Another task failed and specified Error Policy = Fail (See Maintenance Concepts to learn more about Error Policies) |
ERROR_WHILE_GETTING_DEVICE_LICENSES | The task will not execute - and error was returned when DPOD was communicating with the monitored device. |
PLAN_FAILED_PRE_SCRIPT | The task will not execute - the pre-plan script returned with a return code greater than 0 |
EXECUTION_CANCELED_BECAUSE_A_DAY_PASSED | The task was not executed - it was automatically canceled because more than 24 hours passed since it started to wait for execution |
EXECUTION_CANCELED_BECAUSE_MAINTENANCE_WINDOW | The task was not executed - the current time is not within the maintenance window (see Maintenance Concepts for more information about the maintenance window), the maintenance window is checked for all execution types - schedules, ad-hoc via the UI and via the REST API |
READY_FOR_EXECUTION | Interim status - the task passed all validation, it is queued and will be executed in the next minute, or is waiting for other tasks to finish executing first. |
SENT_TO_MDB | Interim status - the task is executing |
EXECUTION_PRE_CHECKS_FOUND_QUIESCED_DOMAIN_IN_DEVICE | Task failed - one or more domains are quiesced, unquiesce all domains before running the upgrade |
EXECUTION_PRE_CHECKS_DEVICE_FIRMWARE_LEVEL_CHANGED | Task failed - The firmware level of the device was changed by an external party during the upgrade task execution, DPOD will assume that another upgrade (manual or by DPOD) is running and will stop the execution |
EXECUTION_PRE_CHECKS_DEVICE_NOT_FOUND | Task failed - the DataPower device was not available, or not found in DPOD managed devices. |
EXECUTION_WAITING_FOR_PRE_SCRIPT | Waiting for the user pre script to execute |
EXECUTION_PRE_SCRIPT_ERROR | Task failed - the user pre task script return code was larger than 0, the post task script will still be executed (if specified) |
EXECUTION_FIRST_QUIESCE_STARTED | Quiesce domain/device started |
EXECUTION_FIRST_QUIESCE_WAITING_FOR_QUIESCE | Waiting for the device or domain to quiesce |
EXECUTION_FIRST_QUIESCE_TIMEOUT_OCCURRED | A timeout occurred while waiting for the device or domain to quiesce, the timeout can be configured - see Configurable Parameters and Settings |
EXECUTION_RESTART_TIMEOUT_OCCURRED | A timeout occurred while waiting for the device to restart, the timeout can be configured - see Configurable Parameters and Settings |
EXECUTION_RESTART_WAITING_FOR_RESTART | DPOD is waiting for the device to restart |
EXECUTION_WAIT_AFTER_RESTART_STARTED | DPOD is waiting for the time specified in the activity definition (this can only happen after a restart was completed successfully) |
EXECUTION_UPLOAD_IMAGE_STARTED | DPOD is uploading the image file to the device |
EXECUTION_UPLOAD_IMAGE_ERROR | Task failed - error occurred while uploading the image file to the device, DPOD uses a script to upload the file - search the logs for "EXECUTION_UPLOAD_IMAGE_ERROR" to see the detailed output the script. |
EXECUTION_UPGRADE_STARTED | DPOD started the firmware upgrade on the monitored device. |
EXECUTION_UPGRADE_WAITING_FOR_UPGRADE | The upgrade was started, the device will restart during the process, DPOD is waiting for the device to finish the upgrade |
EXECUTION_UPGRADE_TIMEOUT_OCCURRED | Task failed - DPOD waited for the device to upgrade more than the time that was specified in the activity definition |
EXECUTION_UNQUIESCE_ON_ERROR_STARTED | An error occured in a previous state while the device was quiesced, DPOD is unquiescing the device before ending the task |
EXECUTION_UNQUIESCE_ON_ERROR_WAITING_FOR_UNQUIESCE | An error occured in a previous state while the device was quiesced, DPOD is unquiescing the device before ending the task |
EXECUTION_UNQUIESCE_ON_ERROR_TIMEOUT_OCCURRED | An error occured in a previous state while the device was quiesced, DPOD tryed to unquiesce the device before ending the task, but aa timeout occurred while waiting for the device to unquiesce, the timeout can be configured - see Configurable Parameters and Settings (DPOD will add 3 minutes to the specified timeout) |
EXECUTION_UPLOAD_IMAGE_EXCEPTION | An internal error occurred, a UUID will be printed, search the logs for this UUID in order to get more information |
EXECUTION_FAILED_WITH_INTERNAL_EXCEPTION | Internal error occurred, see error message for details |
EXECUTION_FAILED_LONG_RUNNING | The task was running for more than 60 minutes (see Configurable Parameters and Settings on how to change this duration) and was marked as finished, the task may still be executing, manual intervention may be required |
SUCCESS | The upgrade finished successfully |