IBM DataPower Operations Dashboard v1.0.18.0

Note: A more recent version of DPOD is available. See DPOD Documentation for the latest documentation.

Known Limitations

Changes to gateway objects

No support for DHCP

Maintenance plan limitations

  • DPOD includes several operations maintenance plans to assist in the day to day operational tasks, such as backups, configuration sync, firmware upgrade, etc.

  • As these features have system wide influence and might affect the availability of the Gateway and services, they include limitations on the usage of the features.

  • For backups - see limitations here.

  • For configuration sync - see limitations here.

  • For firmware upgrades - see limitations here.

  • For appliance migration - see limitations here.

DPOD Operating System supported locale

  • The only supported operating system locale definition for DPOD is en_US.UTF-8 as described in the installation prerequisites.

  • Object names in non-English languages may be partially supported.

Limited functionality is provided when DataPower has a language different than English

  • Choosing a language in DataPower will impact the content of the Syslog records sent to DPOD. This will cause DPOD to provide a limited analysis on records that are not in English.

  • Known workarounds: Change the language of your monitored device to English (en).

Partial support for tenant feature

  • In DataPower firmware 7.6, the tenant module was introduced only to physical appliance type 8436.

  • On tenant devices, only capturing transactions is supported.

  • The following features are currently not supported for tenant devices:

    • Device resource monitoring (CPU, memory, etc.)

    • Maintenance plans (Backup, Sync, Firmware Upgrade)

    • Extended Transaction

Transactions under the default domain are not monitored

  • This limitation is derived from a limitation of the monitored device.

  • Log targets defined at the default domain collect all logs from all domains, and currently there is way to apply a filter to the log targets in order to filter out logs from other application domains.

  • Known workarounds: See Monitoring Transactions in the Default Domain for more details.

Limitation on the number of domains that DPOD can monitor on a single gateway

  • Since the DataPower gateway currently supports up to 1,000 log targets, DPOD can monitor a maximum of 333 domains per each gateway, if no other custom log targets are defined. See details and calculation below for more information.
    This limitation is per each DataPower gateway and has no effect on the number of gateways that can be connected to DPOD.

  • The total amount of log targets per each DataPower gateway cannot exceed 1,000 and consists of:

    • One required default log target per domain (created when the domain is created with the name default-log), which cannot be removed.

    • Additional custom log targets, created by the customer for non-DPOD use.

    • Log targets created by DPOD - DPOD will create one log target for the default domain, and 2 log targets for each monitored application domain.

  • Before you enable DPOD monitoring:

    • Count how many domains should be monitored by DPOD (except the default domain) - DOMAINS_COUNT

    • Count how many log targets already exist in the DataPower gateway - EXISTING_LOG_TARGETS_COUNT
      You can view the existing log targets in the DataPower gateway WebGUI under default domain → Log Target Status → Show All Domains

    • Make sure the following calculation is true:

      EXISTING_LOG_TARGETS_COUNT + (DOMAINS_COUNT x 2) + 1 < 1,000
  • Known workarounds: If the number of expected log targets exceeds the limit, do not enable DPOD monitoring. You may use the following methods to allow for DPOD monitoring:

    • Reduce the amount of monitored domains by setting up monitoring only for selected domains (see Configuring Monitored Gateways).

    • Delete unused domains or move domains to another gateway.

    • Delete unused custom log targets that were created for non-DPOD use.

B2B support is limited

  • Only the most important B2B features (e.g.: transaction details) are supported.

DPOD integration with API-C can be applied to only a single API Connect domain per DataPower Gateway for firmware lower than 7.6

  • This limitation is derived from a limitation of the monitored device.

  • Known workarounds: Upgrade to firmware 7.6 / 7.5.2.8 or later.

WS-M does not capture multi-protocol Gateway services payloads for firmware lower than 7.5.2

  • This limitation is derived from a limitation of the monitored device.

  • Known workarounds:  Upgrade to firmware 7.5.2.1 or later.

 

Copyright © 2015 MonTier Software (2015) Ltd.