IBM DataPower Operations Dashboard v1.0.10.0
A newer version of this product documentation is available.
You are viewing an older version. View latest at IBM DPOD Documentation.
DPOD SSH Session Disconnects Often
As part of the appliance hardening, a short timeout value (300 seconds) is set for the SSH session.
If you need to perform long-running system activities, please issue the following commands:
Â
disable ssh disconnect
sed -i '/^.*ClientAliveInterval.*$/d' /etc/ssh/sshd_config sed -i '/^.*ClientAliveCountMax.*$/d' /etc/ssh/sshd_config service sshd restart
Once your long running activity has completed, issue the following commands to reinstate the short timeout settings.
sed -i 's/^.*ClientAliveInterval.*$/#ClientAliveInterval 300/' /etc/ssh/sshd_config sed -i 's/^.*ClientAliveCountMax.*$/#ClientAliveCountMax 0/' /etc/ssh/sshd_config service sshd restart