Syslog Format for Flatline/ Frequency alerts


NameExampleDescription
Syslog facility code<16>Always <16>
TimeOct 23 15:40:43Alert's execution time
DPOD server host namedpod The host name of DPOD server that generated the alert
Alerts Syslog Message ID[0x00a0001a]Always [0x00a0001a]
Category[DPOD-alert]Always [DPOD-alert]
Severity Level[info]May be set via System Parameters ("Syslog Severity Field Value")
Alert NameAlertName:(Devices CPU Metric)The alert name as defined in Alerts Setup
Alert DescriptionAlertDesc:(Alert on Devices CPU over 80%)The alert description as defined in Alerts Setup
Alerted Objecton:(idg77)The object (device, service, message, etc.) the alert was generated on
Alert ValueValue:(85.0)The query's result value
Alert ThresholdThreshold:(75.0)The alert error threshold as defined in Alerts Setup
Alert FiltersFilters:[device(),domain(),service()]Additional criteria for the alert's execution
Time RangeInterval:[timestampStart(10/23/2018 15:35:43.714),timestampStartLong(1540298143714),
timestampEnd(10/23/2018 15:40:43.714),timestampEndLong(1540298443714)]

The time frame for the alert's execution

Syslog Format for Any/ List alerts 


NameExampleDescription
Syslog facility code<16>Always <16>
TimeOct 24 08:30:23Alert's execution time
DPOD server host namedpod The host name of DPOD server that generated the alert
Alerts Syslog Message ID[0x00a0001a]Always [0x00a0001a]
Category[DPOD-alert]Always [DPOD-alert]
Severity Level[info]May be set via System Parameters ("Syslog Severity Field Value")
Alert NameAlertName:(Objects Down Alert)The alert name as defined in Alerts Setup
Alert DescriptionAlertDesc:(Alert on any DP object that is enabled but down)The alert description as defined in Alerts Setup
Alerted Objecton:([Domain is down, LogTarget, idg77, HospitalA_Domain])The object (device, service, message, etc.) the alert was generated on
Alert ValueValue:(null)The alert value is not applicable for alert types "any" and "list"
Alert ThresholdThreshold:(null)The alert threshold is not applicable for alert types "any" and "list"
Alert FiltersFilters:[device(),domain(),service()]Additional criteria for the alert's execution
Time RangeInterval:[timestampStart(10/24/2018 08:25:23.531),timestampStartLong(1540358723531),
timestampEnd(10/24/2018 08:30:23.531),timestampEndLong(1540359023531)]

The time frame for the alert's execution