Removing Unused Properties from the Retention Configuration File

The following steps apply to all DPOD installations (All-in-One, cell manager and cell members).

  1. Some installations might have unused properties in the retention configuration file, which may cause the upgrade to 1.0.16.0 to fail with the following error:

    File /app/hk_retention/MonTier-HK-ESRetention/conf/MonTierHousekeeping.conf contains placeholders
  2. Before applying the upgrade to 1.0.16.0, please execute the following commands:

    sed -i '/elasticsearch\.index\_set\.logical\-tran\-full\.max\_size\=.*/d' /app/hk_retention/MonTier-HK-ESRetention/conf/MonTierHousekeeping.conf
    sed -i '/elasticsearch\.index\_set\.iib\-log\-tran\.max\_size=.*/d' /app/hk_retention/MonTier-HK-ESRetention/conf/MonTierHousekeeping.conf
    sed -i '/elasticsearch\.index\_set\.iib\-stats\-tran\.max\_size=.*/d' /app/hk_retention/MonTier-HK-ESRetention/conf/MonTierHousekeeping.conf

Internal Alerts May Appear About the Reindex Manager

After the upgrade to 1.0.16.0 completes successfully, the following internal alert may appear once or twice:

A critical service is not working: Could not find the latest successful Reindex Manager execution

This is expected and does not indicate an issue with the installation.

However, if the internal alert is triggered continuously, please open a support case.