Appliance Mode Users Only - Upgrade Should be Applied in 2 Steps

The upgrade will upgrade your DPOD installation to an advanced level of Operating System (CentOS 7.7). Therefore the upgrade command will be required to be executed twice:

  1. For operating system upgrade
  2. For application software upgrade

Issue in Upgrading Cell Environment from 1.0.9.0 to 1.0.10.1

DPOD 1.0.10.1 has an issue that causes upgrades to fail in a cell environment. Follow the instructions below to avoid this issue.

  1. Before running the upgrade, execute the following commands on each of the cell members:

    # Cell MEMBERS only!
    mv /app/agentnode /app/agentnode-old
    mv /etc/init.d/MonTier-AgentNode /etc/init.d/Disabled-MonTier-AgentNode
  2. Before running the upgrade, execute the following commands on the cell manager:

    # Cell MANAGER only!
    mv /app/agentnode /app/agentnode-old