IBM DataPower Operations Dashboard v1.0.15.0

A newer version of this product documentation is available.

You are viewing an older version. View latest at IBM DPOD Documentation.

Skip to end of metadata
Go to start of metadata

You are viewing an old version of this page. View the current version.

Compare with Current View Page History

« Previous Version 7 Next »

Appliance Mode Users Only - Upgrade should be Applied in 2 Steps

The upgrade will update your DPOD installation Operating System (CentOS 7.8). Therefore the upgrade command will be required to be executed twice:

  1. For operating system update
  2. For application software upgrade

Before applying the update, as a prerequisites, make sure to execute the following command:

yum -y remove samba-common-tools pcp-pmda-lustrecomm pcp-pmda-cisco NetworkManager-ppp python-pcp pcp-pmda-mailq \
avahi-autoipd rsyslog-mmjsonparse pcp-pmda-lustrecomm postfix-perl-scripts pcp-pmda-apache pcp-pmda-dm \
pcp-pmda-logger pcp-system-tools pcp-pmda-summary pcp-pmda-weblog pcp-pmda-rpm pcp-pmda-sendmail \
pcp-pmda-gfs2 pcp-pmda-nvidia-gpu libgudev1 python-pcp pcp-pmda-roomtemp pcp-pmda-lmsensors pcp-pmda-bash \
pcp-pmda-trace pcp-pmda-mounts pcp-pmda-shping perl-PCP-PMDA 

Issue in Upgrading Cell Environment from 1.0.10.X to 1.0.11.0

DPOD 1.0.11.0 has an issue that causes upgrades to fail for a cell environment. Follow the instructions below to avoid this issue.

Before running the upgrade, execute the following commands on BOTH the cell manager and all the cell members:

mkdir -p /app/agentnode/MonTier-AgentNode/conf && touch /app/agentnode/MonTier-AgentNode/conf/MonTierAgentNode.conf


  • No labels