Change DPOD ElasticSearch alias entry in /etc/hosts to bind to external IP address
Code Block vi /etc/hosts
and change the line
Code Block 127.0.0.1 montier-es
to DPOD's internal console IP address (e.g. 1.1.1.1)
Code Block 1.1.1.1 montier-es 1.1.1.1 montier-es-http
Ensure all components are up and running
Code Block app_status.sh #Output Example: MonTier-AppAdmin (pid 17836) is running... MonTier-Derby (pid 17940) is running... MonTier-es-raw-trans-Node-1 (pid 18125) is running... MonTier-es-raw-trans-Node-2 (pid 21122) is running... MonTier-es-raw-trans-Node-3 (pid 21103) is running... MonTier-es-raw-trans-Node-4 (pid 21120) is running... MonTier-SyslogAgent-1 (pid 27350) is running... MonTier-SyslogAgent-2 (pid 27286) is running... MonTier-SyslogAgent-3 (pid 27177) is running... MonTier-SyslogAgent-4 (pid 27075) is running... MonTier-WsmAgent-1 (pid 27002) is running... MonTier-WsmAgent-2 (pid 26921) is running... MonTier-WsmAgent-3 (pid 26881) is running... MonTier-WsmAgent-4 (pid 26773) is running... MonTier-HK-ESRetention (pid 24012) is running... MonTier-HK-WdpDeviceResources (pid 27590) is running... MonTier-HK-WdpServiceResources (pid 27447) is running... MonTier-HK-SyslogKeepalive (pid 1976) is running... MonTier-HK-WsmKeepalive (pid 1932) is running... MonTier-UI (pid 1635) is running... MonTier-Reports (pid 1830) is running... MonTier-AgentNode (pid 1736) is running...
DPOD External Self-Service post installation checks
To verify the DPOD External Self-Service installation, start the External console and ensure all is working as expected.
...
Ensure all required components are up:
The following components must be running:
...
Enure the UI components is up using ElasticSearch Client mode connection.
Inside the UI log file at /logs/ui/ MonTier-UI.log locate the following line:
Code Block |
---|
04/04/2016 06:55:53,941- DEBUG o.m.c.u.e.ElasticSearchClient [montier-ui-server-startStop-1] Connecting to ElasticSearch as transport client |
...
- Start DPOD's console and sign in: http://<DPOD Server>/
- Ensure the System Overview dashboard contains data
- Ensure the Investigate screen contains data.