IBM DataPower Operations Dashboard v1.0.16.0

A newer version of this product documentation is available.

You are viewing an older version. View latest at IBM DPOD Documentation.

Publish Backup Events via Syslog and Email

Setup

  1. The Maintenance Configurable Parameters page provides information on how to setup the syslog destination.
  2. The Email destination is configured in the plan definition.
  3. Configure the SMTP parameters from the System Parameters Page, see the System Parameters List Page for a description of each parameter.
  4. If you set a value for "The HTTP Address of the UI" parameter - a link to the DPOD UI will be added to the emails with a shortcut to the relevant plan or task execution results.

The following events will be published via Email and/or syslog (as defined in the backup plan):

Plan Events

Backup Plan Completed Successfully
All backup tasks finished successfully
Syslog Message Id - 0x00a0300a


Backup Plan Completed Successfully with Skipped Tasks
Some backup tasks finished successfully and some were skipped (but none failed)
Syslog Message Id - 0x00a0301a


Backup Plan Failed
At least one task failed
Syslog Message Id - 0x00a0302a

Task Events

Backup Task Completed Successfully
A backup task finished execution, and all files downloaded to the user's storage
Syslog Message ID - 0x00a0100a


Backup Task Failed
A backup task failed for any reason
Syslog Message ID - 0x00a0101a


Backup Task - Found Unsaved Changes in Domain (Export-Domain tasks only)
When unsaved changes are found in the domain, DPOD will create backups for both persisted and non-persisted changes, and a warning message will be issued.
Syslog Message ID - 0x00a0102a

Backup Task Skipped
When a backup task did not execute - e.g. when the device was unavailable
Syslog Message ID - 0x00a0103a


Backup Task Long Running
If a task's status did not change for more than 60 minutes (see Maintenance Configurable Parameters for more information), DPOD will issue the "Long Running" event and will consider the task as finished
Syslog Message ID - 0x00a0104a

Backup Task was not Executed
For tasks that passed all validations but did not execute. E.g. when the maintenance window timeframe ended before the task was executed
Syslog Message ID - 0x00a0105a



IBM DataPower Operations Dashboard (DPOD) v1.0.16.0