Updating Store Allocation in 1.0.9.0-1.0.11.0 Results in Wrong Retention Configuration

IBM DataPower Operations Dashboard v1.0.12.0

A newer version of this product documentation is available.

You are viewing an older version. View latest at https://ibm.biz/dpod-docs.

Updating Store Allocation in 1.0.9.0-1.0.11.0 Results in Wrong Retention Configuration

Symptoms

  • Store allocation is updated, for example after increasing the Store space.

  • /data mount point has some data when store allocation was updated, so it was not 100% free.

  • DPOD does not utilize the store space, only a part of it, so history is limited more than it should be.

  • DPOD version is 1.0.9.0-1.0.11.0
    Note: DPOD 1.0.11.0-iFix1 fixed this issue

Cause

A bug in the store allocation update script is using the free space instead of the total space for evaluating the store space.

Resolution

  • DPOD should be upgraded to version 1.0.11.0-iFix1 or higher.

  • Once DPOD is upgraded, Store allocation should be updated again.

IBM DataPower Operations Dashboard (DPOD) v1.0.12.0