IBM DataPower Operations Dashboard v1.0.10.0

A newer version of this product documentation is available.

You are viewing an older version. View latest at IBM DPOD Documentation.

Firmware Upgrade - User Defined Scripts

DPOD allows execution of user defined, custom scripts before and after both Plan and Task execution.
The scripts are executed from /app/custom/scripts (See Configurable Parameters and Settings for information on how to change this path)

Any script that returns a return code larger than 0 is considered to have failed.

if a pre-plan or a pre-task script failed - the plan or task will be flagged as failed and will not execute.
If a pre-task script failed, the post-task script will still be executed (if requested)


DPOD will send certain parameters to the script, to indicate the execution details and completion status.

Parameters Sent to the Firmware Upgrade Pre-Plan Script

Sample script: /app/custom/scripts/firmware_upgrade_pre_plan_sample.sh

1=PLAN_TYPE - The constant "FIRMWARE-UPGRADE-PLAN"
2=PLAN_STAGE - The constant "PRE"
3=PLAN_ID - The ID of the firmware upgrade plan
3=PLAN_NAME - The name of the firmware upgrade plan

 Example:
1=FIRMWARE-UPGRADE-PLAN
2=PRE
3=16
4=firmware1

Parameters Sent to the Firmware Upgrade Post-Plan Script

Sample script: /app/custom/scripts/firmware_upgrade_post_plan_sample.sh

1=PLAN_TYPE - The constant "FIRMWARE-UPGRADE-PLAN"
2=PLAN_STAGE - The constant "POST"
3=PLAN_ID - The ID of the firmware upgrade plan
4=PLAN_NAME - The name of the firmware upgrade plan
5=FINAL_STATUS_CODE - Final status code of the firmware upgrade plan
6=FINAL_ERROR_MSG - Final error message of the firmware upgrade plan, or "NONE" if there were no errors
7=FFU1 - The constant "FFU" (For future use)
8=FFU2 - The constant "FFU" (For future use)
9=TASKS_VALUES - list of comma separated values for each task - task ID, device name, version before execution, version after execution, task status  - different tasks are separated with ~ (Tilde sign) 

Example:
1=FIRMWARE-UPGRADE-PLAN
2=POST
3=16
4=firmware1
5=SUCCESS
6=NONE
7=FFU
8=FFU
9=13,IDG-QA-2,IDG.7.5.0.17,IDG.7.5.2.10,SUCCESS~14,IDG-QA-3,IDG.7.5.0.17,IDG.7.5.2.10,SUCCESS

Parameters Sent to the Firmware Upgrade Pre-Task Script

Sample script: /app/custom/scripts/firmware_upgrade_pre_task_sample.sh

1=TASK_TYPE - The constant "FIRMWARE-UPGRADE-TASK"
2=TASK_STAGE - The constant "PRE"
3=TASK_ID - The ID of the firmware upgrade task
4=PLAN_NAME - The name of the firmware upgrade plan that generated this task
5=DEVICE_NAME - The name of the device
6=DEVICE_HOST - The host of the device
7=SOMA_PORT - The soma port of the device
8=VERSION_BEFORE - The firmware version of the device before the task started
9=IMAGE_FILE_NAME - the image file name to use for the upgrade

Example:
1=FIRMWARE-UPGRADE-TASK
2=PRE
3=12
4=firmware1
5=IDG-QA-2
6=192.168.72.100
7=5550
8=IDG.7.5.0.17
9=idg75210.oradco.scrypt4

Parameters Sent to the Firmware Upgrade Post-Task Script

Sample script: /app/custom/scripts/firmware_upgrade_post_task_sample.sh

1=TASK_TYPE - The constant "FIRMWARE-UPGRADE-TASK"
2=TASK_STAGE - The constant "POST"
3=TASK_ID - The ID of the firmware upgrade task
4=PLAN_NAME - The name of the firmware upgrade plan that generated this task
5=FINAL_STATUS - Final status code of the firmware upgrade task
6=FINAL_ERROR_MSG - Final error message of the firmware upgrade task, or "NONE" if there were no errors
7=FFU1 - The constant "FFU" (For future use)
8=FFU2 - The constant "FFU" (For future use)
9=DEVICE_NAME - The name of the device 
10=DEVICE_HOST - The host of the device
11=SOMA_PORT - The soma port of the device
12=VERSION_BEFORE - The firmware version string before the task was started
13=VERSION_AFTER- The firmware version string after the task finished
14=IMAGE_FILE_NAME - the image file name to use for the upgrade

Example:
1=FIRMWARE-UPGRADE-TASK
2=POST
3=13
4=firmware1
5=SUCCESS
6=NONE
7=FFU
8=FFU
9=IDG-QA-2
10=192.168.72.100
11=5550
12=IDG.7.5.0.17
13=IDG.7.5.2.10
14=idg75210.oradco.scrypt4

IBM DataPower Operations Dashboard (DPOD) v1.0.10.0