IBM DataPower Operations Dashboard v1.0.8.5

Note: A more recent version of DPOD is available. See IBM DPOD Documentation for the latest documentation.

Backup Tasks Status Codes

Here are some common statuses for Backup task executions.

Status CodeDescription
WAITING_FOR_PRE_VALIDATIONThe task was entered into the execution queue, it was not yet validated or checked, and eventually may not get executed
SKIPPED_APIC_DOMAINThe task will not execute - cannot backup API Connect domain
SKIPPED_DEVICE_NOT_AVAILABLEThe task will not execute - the device was not available
SKIPPED_NO_DEVICES_MATCHING_PATTERNThe task will not execute - no devices were matching the device pattern requested in the activity
DEVICE_NOT_IN_DR_MODEThe task will not execute - Secure Backup requested, but the device was not in DR mode
NOT_ENOUGH_FREE_SPACE_ON_DEVICEThe task will not execute - There is not enough free space in the DataPower temp storage (see Configurable Parameters and Settings on how to change the check's threshold)
CERT_DOESNT_EXIST_ON_DEVICEThe task will not execute - The certificate specified for Secure Backup was not found on the device
SKIPPED_BECAUSE_ERROR_POLICY
EXECUTION_CANCELED_BECAUSE_ERROR_POLICY
The task will not execute - Another task failed and specified Error Policy = Fail (See Maintenance Concepts to learn more about Error Policies)
PLAN_FAILED_PRE_SCRIPTThe task will not execute - the pre-plan script returned with a return code greater than 0
EXECUTION_CANCELED_BECAUSE_A_DAY_PASSEDThe task was not executed - it was automatically canceled because more than 24 hours passed since it started to wait for execution
EXECUTION_CANCELED_BECAUSE_MAINTENANCE_WINDOWThe task was not executed - the current time is not within the maintenance window (see Maintenance Concepts for more information about the maintenance window), the maintenance window is checked for all execution types - schedules, ad-hoc via the UI and via the REST API
READY_FOR_EXECUTIONInterim status - the task passed all validation, it is queued and will be executed in the next minute, or is waiting for other tasks to finish executing first.
SENT_TO_MDB
EXECUTION_STARTED
EXECUTION_PRE_CHECKS_STARTED
Interim status - the task is executing
EXECUTION_PRE_CHECKS_FOUND_QUIESCED_DOMAIN_IN_DEVICETask failed - quiesce deice requested (for Secure Backup or Export all domains) but found a domain that was already quiesced
EXECUTION_PRE_CHECKS_DOMAIN_IS_ALREADY_QUIESCEDTask failed - quiesce domain requested but the domain was already quiesced
EXECUTION_PRE_CHECKS_NFS_OUT_OF_SPACETask failed - The specified backup destination is out of space,  see Configurable Parameters and Settings on how to check this check threshold
EXECUTION_PRE_CHECKS_NFS_DIRECTORY_NOT_FOUNDTask failed - The specified backup destination was not found,  see Configurable Parameters and Settings on how to change the destination
EXECUTION_PRE_CHECKS_DEVICE_NOT_AVAILABLETask failed - the DataPower device was not available
EXECUTION_CHECK_MANIFEST_WAITING_FOR_ANOTHER_BACKUPThe task is waiting for another DPOD backup task to finish running on the device
EXECUTION_CHECK_MANIFEST_ANOTHER_SECURE_BACKUP_IS_RUNNING_CHECK_DEVICETask failed - this may happen if DPOD was restarted while a backup task was running, it seems that the backup task is still executing, but DPOD lost track of it, check the device manually.
EXECUTION_WAITING_FOR_PRE_SCRIPTWaiting for the user pre script to execute
EXECUTION_PRE_SCRIPT_ERRORTask failed - the user pre task script return code was larger than 0, the post task script will still be executed (if specified)
EXECUTION_QUIESCE_STARTEDQuiesce domain/device started
EXECUTION_QUIESCE_WAITING_FOR_QUIESCEWaiting for the device or domain to quiesce
EXECUTION_QUIESCE_TIMEOUT_OCCURREDA timeout occurred while waiting for the device or domain to quiesce, the timeout can be configured -  see Configurable Parameters and Settings
(DPOD will add 3 minutes to the specified timeout)
EXECUTION_EXPORT_DOMAIN_PERSISTED_STARTED
EXECUTION_EXPORT_DOMAIN_NON_PERSISTED_STARTED
Export-Domain started
EXECUTION_EXPORT_DOMAIN_PERSISTED_SOMA_ERROR
EXECUTION_EXPORT_DOMAIN_NON_PERSISTED_SOMA_ERROR
Error occurred in the Export-Domain process
EXECUTION_EXPORT_DOMAIN_PERSISTED_EMPTY_FILE
EXECUTION_EXPORT_DOMAIN_NON_PERSISTED_EMPTY_FILE
The Export Domain process returned an empty file
EXECUTION_EXPORT_DOMAIN_PERSISTED_SAVEFILE_EXCEPTION
EXECUTION_EXPORT_DOMAIN_NON_PERSISTED_SAVEFILE_EXCEPTION
An error occurred while saving the Export Domain zip file to DPOD
EXECUTION_EXPORT_DOMAIN_PERSISTED_DONE
EXECUTION_EXPORT_DOMAIN_NON_PERSISTED_DONE
Export-Domain finished successfully
EXECUTION_SECURE_BACKUP_STARTEDSecure Backup started
EXECUTION_SECURE_BACKUP_UNSUCCESSFULSecure Backup returned an error
EXECUTION_SECURE_BACKUP_WRONG_FILE_HASH
EXECUTION_SECURE_BACKUP_WRONG_FILE_SIZE
EXECUTION_SECURE_BACKUP_EMPTY_FILE
Downloading the Secure Backup files from the DataPower temp folder to DPOD failed
EXECUTION_UNQUIESCE_STARTED
EXECUTION_UNQUIESCE_ON_ERROR_STARTED
Unquiesce domain/device started
EXECUTION_UNQUIESCE_WAITING_FOR_UNQUIESCE
EXECUTION_UNQUIESCE_ON_ERROR_WAITING_FOR_UNQUIESCE
Waiting for domain/device to unquiesce
EXECUTION_UNQUIESCE_TIMEOUT_OCCURRED
EXECUTION_UNQUIESCE_ON_ERROR_TIMEOUT_OCCURRED
A timeout occurred while waiting for the device or domain to unquiesce, the timeout can be configured -  see Configurable Parameters and Settings (DPOD will add 3 minutes to the specified timeout)
EXECUTION_FAILED_WITH_INTERNAL_EXCEPTIONInternal error occurred, see error message for details
EXECUTION_FAILED_LONG_RUNNINGThe task was running for more than 60 minutes (see Configurable Parameters and Settings on how to change this duration) and was marked as finished, the task may still be executing, manual intervention may be required
FAILED_NO_FILES_DOWNLOADEDNo errors occurred, but no files downloaded to DPOD - this may happen if DPOD was restarted during the backup process
Try to run the backup again
SUCCESSThe backup finished successfully





IBM DataPower Operations Dashboard (DPOD) v1.0.8.5