IBM DataPower Operations Dashboard v1.0.11.0

A newer version of this product documentation is available.

You are viewing an older version. View latest at IBM DPOD Documentation.

Skip to end of metadata
Go to start of metadata

You are viewing an old version of this page. View the current version.

Compare with Current View Page History

« Previous Version 2 Current »

Symptoms

  • Attempting to add a new gateway to DPOD results in the following error message:
    The device's system identifier does not equal to <Gateway Name>
  • However, the system identifier (appliance name) is exactly the same as the name provided in DPOD for that gateway when trying to add it.

Cause

  • The gateway user provided to DPOD cannot make SOMA requests to the gateway, and DPOD fails to read the real system identifier (appliance name) of the gateway.
  • SeeĀ Prepare your Monitored Devices for more information.

Resolution

  • First make sure the system identifier (appliance name) in the gateway's Web GUI is exactly the same as provided to DPOD when adding the gateway.
  • Make sure the user is privileged in the gateway's Web GUI.
  • Try to login with the privileged user and reset its password if indeed it expired.


  • No labels