Alerts
Name | Description |
---|---|
API Latency Above 100ms Alert | Alert if more than 5 API Connect API calls finished with latency of over 100ms Change 5 to any other number using the field "Error Threshold" To change "100" to any other latency, you will need to edit the JSON - duplicate the alert first, as system predefined alerts' JSON cannot be edited |
About to Expire Certificates Alert | Alert for certificates that are about to expire. The alert will check for syslog message with code 0x806000e2 that were written in the last 24 hours |
Already Expired Certificates Alert | Alert for certificates that already expired - the alert will check for syslog messages with code 0x806000e1 that were written in the last 24 hours |
Domain Restarts Alert | Alert on domain restarts |
Message Codes Frequency Alert | Alert when message codes frequency exceeds threshold value. |
Number of Probes Alert | Alert if more than 1000 transactions with probles were run in the last 10 minutes |
Objects Down Alert | Alert on all the DataPower objects that are enabled in configuration but in a down state (similar to the data shown in the Failed Objects page) |
Syslog Errors MessageCode Alert | Alert when a specific syslog message is written (only messages with severity = error) |
Transaction Errors Alert | Alert when 5 or more transactions with errors ran in the last 30 minutes Please note: When duplicating this alert - the new alert name must start with "Transaction_Errors" (e.g. "Transaction_Errors_2") |
System Health Metrics
See System Health for more detailes
Name | Description |
---|---|
Devices CPU Metric 1 | Alert when the max device CPU during the last 5 minutes was over 80% |
Devices Fan Metric 1 | Alert when the device fan health is less than 100% |
Devices Load Metric 1 | Alert when the max device load in the last 5 minutes was more than 80% |
Devices Memory Metric 1 | Alert when the max used memory of the device in the last 5 minutes was over 70% |
Devices Space Encrypted Metric 1 | Alert if the free space of the encrypted file system is less than 15% |
Devices Space Internal Metric 1 | Alert if the free space of the internal file system is less than 15% |
Devices Space Temp Metric 1 | Alert if the free space of the temporary file system is less than 15% |
Devices Temperature Metric 1 | Alert when the device temperature health is less than 100% |
Devices Voltage Metric 1 | Alert if the device's voltage health is less than 100% |
System Errors Metric | Alert if more than 10 critical system errors were written to syslog in the last 5 minutes |
(1) The following alerts and metrics are valid only for devices with the option "Device Resources Monitoring" enabled. You may edit the device setting from [Manage → Devices → Monitored Devices].
See also Adding Monitored Devices.