Certificates that are About to Expire
Alert for certificates that are about to expire. The alert will check for syslog message with code 0x806000e2 that were written in the last 24 hours
Certificates that Already Expired
Alert for certificates that already expired - the alert will check for syslog messages with code 0x806000e1 that were written in the last 24 hours
Number of Probes
Alert if more than 1000 transactions with probles were run in the last 10 minutes
DataPower Objects that are Enabled But Down
Alert on all the DataPower objects that are enabled in configuration but in a down state (similar to the data shown in the Failed Objects page)
Syslog Errors with a Specific Message Code
Alert when a specific syslog message is written (only messages with severity = error)
You will need to edit this alert and enter the message codes to alert on instead of the supplied sample message code (0x81000098)
Number of Critical System Errors
Alert if more than 10 critical system errors were written to syslog in the last 5 minutes
Transaction_Errors
Alert when 5 or more transactions with errors ran in the last 30 minutes
Please note: When duplicating this alert - the new alert name must start with "Transaction_Errors" (e.g. "Transaction_Errors_2")
The following alerts will return data only if you selected the "Device Resources monitoring" option during the device's setup
You may edit the device setting from [Manage → Devices → Monitored Devices]
Device Temperature Health
Alert when the device temperature health is less than 100%
Device CPU
Alert when the max device CPU during the last 5 minutes was over 80%
Device Fan Health
Alert when the device fan health is less than 100%
Device Load
Alert when the max device load in the last 5 minutes was more than 80%
Device Memory
Alert when the max used memory of the device in the last 5 minutes was over 70%
Free Space of the Encrypted File System
Alert if the free space of the encrypted file system is less than 15%
Free Space of the Internal File System
Alert if the free space of the internal file system is less than 15%
Free Space of the Temporary File System
Alert if the free space of the temporary file system is less than 15%
Device Voltage Health
Alert if the device's voltage health is less than 100%