IBM DataPower Operations Dashboard v1.0.7.1

A newer version of this product documentation is available.

You are viewing an older version. View latest at IBM DPOD Documentation.

Skip to end of metadata
Go to start of metadata

You are viewing an old version of this page. View the current version.

Compare with Current View Page History

« Previous Version 3 Next »

DPOD automatically runs several self diagnostic tests on the following internal components:

  • Derby Database availability
  • ElasticSearch (the Big Data Store) availability
  • File system free space
  • Internal Big Data Retention process
  • Dropped syslog messages
  • Dropped WS-M messages
  • Syslog and WS-M agent status

You can turn off some or all of the checks from by logging in to your DPOD server (via ssh), editing the file: /app/hk_keepalive/MonTier-HK-SyslogKeepalive/conf/MonTierHousekeeping.conf
and restarting the keepalive service via app-util.sh

The internal alerts can be published in two ways:

  1. Via Email - from the system parameters page, change the value of "Internal Alerts - Send Email on Alert" to "true", and enter the email destination in "Internal Alerts - Email Destination Address for Alerts"
  2. Via Syslog - from the system parameters page, change the value of "Internal Alerts - Send Syslog on Alert" to "true",  the syslog destination is identical to the destination of the normal system alerts, and can be configured from the parameters  "Hostname of the target server for syslog alerts" and "Port of the target server for syslog alerts"
  • No labels