IBM DataPower Operations Dashboard v1.0.15.0

A newer version of this product documentation is available.

You are viewing an older version. View latest at IBM DPOD Documentation.

Skip to end of metadata
Go to start of metadata

You are viewing an old version of this page. View the current version.

Compare with Current View Page History

« Previous Version 3 Next »

Appliance Mode Users Only - Upgrade Should be Applied in 2 Steps

The upgrade will update your DPOD installation Operating System (CentOS 7.8). Therefore the upgrade command will be required to be executed twice:

  1. For operating system update
  2. For application software upgrade

Issue in Upgrading Cell Environment from 1.0.10.X to 1.0.11.0

DPOD 1.0.11.0 has an issue that causes upgrades to fail for a cell manager. Follow the instructions below to avoid this issue.

  1. Before running the upgrade, execute the following commands on BOTH the cell manager and all the cell members

    mkdir /app/agentnode/MonTier-AgentNode/conf && touch /app/agentnode/MonTier-AgentNode/conf/MonTierAgentNode.conf