DPOD software updates are available from time to time and include enhancements, security updates, component upgrade, bug fixes etc.
The following sections describe the process of upgrading an existing installation.
To upgrade for v.1.0.9.0 you must be at version v1.0.8.5.
You should consider full backup.
Obtain the software update
DPOD software updates are available through IBM fix central.
The download consists of two types of files :
- The update file in the format of : DPOD-fixpack-<version number>.sfs (for example: DPOD-fixpack-1_0_9.sfs)
- The md5 hash calculation of the update file : DPOD-update-<version number>.md5
Copy the software update to the DPOD server
Copy the update files to the following directory on the DPOD server :
/installs/update/fix/TODO
If the directory is missing for some reason, please re create it :
mkdir -p /installs/update/fix/TODO
Install the software update
Run the following command from the location you downloaded the update files to.
MonTierUpdateInstaller.sh -u DPOD-update-<version number>.sfs -s DPOD-update-<version number>.md5
For example:
MonTierUpdateInstaller.sh -u DPOD-update-1_9_0.sfs -s DPOD-update-1_9_0.md5
After running the command you will be prompted to confirm the software update process. press "Y" to confirm or "N" to abort.
Software update : Please DO NOT interrupt during the process ! Are you sure you want to continue ? [y/n]
When the software update level is not compatible with the current system version you will receive the following message on the console output :
error, software update can NOT be applied to this system version. aborting update...
Do Not interrupt the software update process after it has begun
The upgrade process checks the existence of ElasticSearch indices that were created in early versions of the product.
In case that early version indices do exist, the upgrade process will stop and notify you of a manual step that you will need to run :
The Data-Migration process may run a few minutes, or depending on the amount of data to migrate, up to a few days.
Make sure not to interrupt SSH session during the Data-Migration operation.
Alternatively, you can run the Data-Migration in a "nohup" mode
When the Data-Migration completes, run the upgrade process again.
When the software update completes, the system will display the following messages on the console output.
Starting software update. log file is /installs/update/fix/logs/montier-update-2017-08-01_16-13-35.log stopping application ... application stopped successfully. starting software update..... updated complete successfully starting application ... application started successfully. update DPOD-update-1_5_0.sfs was installed successfully. log file /installs/update/fix/logs/montier-update-2017-08-01_16-13-35.log
Please review the upgrade log file if the console displays any error messages.