Cloud Agent limitations

The Cloud Agent feature is currently supported under the following limitations:

  • You may connect up to 4 Cloud Agents to a DPOD installation.

  • Each Cloud Agent may discover up to 10 DataPower Gateway pods.

  • The cumulative transaction rate of all the DataPower Gateways that are connected via Cloud Agents to a DPOD installation should not exceed 40 TPS.

  • The Cloud Agent operator was tested only on OpenShift.

Changes to gateway objects

...

  • In DataPower firmware 7.6, the tenant module was introduced only to physical appliance type 8436.

  • Only On tenant devices, only capturing transactions on tenant devices is supported.

  • The following features are currently not supported for Tenant tenant devices:

    • Device resource monitoring Appliance Maintenance (CPU, memory, etc.)

    • Maintenance plans (Backup, Sync, Firmware Upgrade)

    • Extended Transaction

...

  • This limitation is derived from a limitation of the monitored device.

  • Log targets defined at the default domain collect all logs from all domains, and currently there is way to apply a filter to the log targets in order to filter out logs from other application domains.

  • Known workarounds: See Monitoring Transactions in the Default Domain for more details.

DPOD integration with API-C can be applied to only a single API Connect domain per DataPower Gateway for firmware lower than 7.6

  • This limitation is derived from a limitation of the monitored device.

  • Known workarounds: Upgrade to firmware 7.6 / 7.5.2.8 or later.

WS-M does not capture multi-protocol Gateway services payloads for firmware lower than 7.5.2

  • This limitation is derived from a limitation of the monitored device.

  • Known workarounds:  Upgrade to firmware 7.5.2.1 or later.

Limitation on the number of domains that DPOD can monitor on a single gateway

  • When there are no Since the DataPower gateway currently supports up to 1,000 log targets, DPOD can monitor a maximum of 333 domains per each gateway, if no other custom log targets are defined on the Gateway, the Gateway supports a maximum of 125 domains that DPOD can monitor.

  • Before firmware 7.5.2.4, the Gateway supported 500 log targets. Because the default domain requires 3 log targets and each application domain requires 2 log targets, The Gateway without custom log targets supports a maximum of 248 domains. After firmware 7.5.2.4 this number were doubled.

  • When you enable DPOD monitoring, one new log target is added to the default domain and 2 new log targets to each . See details and calculation below for more information.
    This limitation is per each DataPower gateway and has no effect on the number of gateways that can be connected to DPOD.

  • The total amount of log targets per each DataPower gateway cannot exceed 1,000 and consists of:

    • One required default log target per domain (created when the domain is created with the name default-log), which cannot be removed.

    • Additional custom log targets, created by the customer for non-DPOD use.

    • Log targets created by DPOD - DPOD will create one log target for the default domain, and 2 log targets for each monitored application domain.

  • Before you can enable DPOD monitoring:

    • View the list of defined domains, to ensure that no more than 125 domains are already defined.

    • Run the show log-targets command in Diagnostics mode to determine the number of log targets that are defined.

  • Known workarounds: Unless the following calculation results in a positive integer, do not enable DPOD monitoring until you move domains to another Gateway:
    Max Log targets per device  - ((domains x 2) - 1) - number_log_targets

B2B support is limited

  • At present,
    • Count how many domains should be monitored by DPOD (except the default domain) - DOMAINS_COUNT

    • Count how many log targets already exist in the DataPower gateway - EXISTING_LOG_TARGETS_COUNT
      You can view the existing log targets in the DataPower gateway WebGUI under default domain → Log Target Status → Show All Domains

    • Make sure the following calculation is true:

      Code Block
      EXISTING_LOG_TARGETS_COUNT + (DOMAINS_COUNT x 2) + 1 < 1,000
  • Known workarounds: If the number of expected log targets exceeds the limit, do not enable DPOD monitoring. You may use the following methods to allow for DPOD monitoring:

    • Reduce the amount of monitored domains by setting up monitoring only for selected domains (see Configuring Monitored Gateways).

    • Delete unused domains or move domains to another gateway.

    • Delete unused custom log targets that were created for non-DPOD use.

B2B support is limited

  • Only the most important B2B features (e.g.: transaction aggregationdetails) are supported. Configuration sampling and specific filtering in dashboards are part of the current version.