Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.
  1. To send Send reports, alerts, internal alerts or maintenance events via Email - setup : Setup the SMTP host, password, port and user name in the system parameters page
  2. To send Send reports via Email - configure the reports Email destination
  3. To publish Publish alerts via syslog - : configure the alerts syslog server hostname and port in the system parameters page
  4. To receive internal Receive internal DPOD health checks alerts via syslog or Email, : enter the Email recipients and change the value for "Internal Alerts - Send Email on Alert" , "Internal Alerts - Email Destination Address for Alerts" and "Internal Alerts - Send Syslog on Alert" in the system parameters pageRestart the keepalive service via app-util.sh after changing these parameters
  5. To publish Publish DPOD maintenance events (backup, sync) via syslog - : configure the maintenance syslog server hostname and port in the system parameters page
  6. If you wish to use Use the backup appliance feature - : change the "Backups -  Destination Path"  in the system parameters page to an external mount point
  7. If you wish to receive Receive Syslog notification for the backup or sync appliance features, : change "Maintenance Syslog Notifications Destination Hostname"  in the system parameters page
  8. Perform some security Security hardening such as: replace self signed certificate of the web console and limit admin dashboard to specific IP address.