Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

  • DPOD serves as a database and should, therefore, be configured to use very fast disks. For this reason, DPOD installation requires 3 separate DISKS  for OS, Installation, and Data.
  • Usage of slow disks is not recommended and . It will impact the maximum TPS that DPOD can process, the performance of queries and the amount of time between the creation of transaction logs and the availability of the data on DPOD's dashboards.
  • For Physical hardware installations that can utilize HW RAID services the following setup is recommended:
    • RAID5 - 40GB - for OS disk
    • RAID5 - 40GB - for App disk
    • RAID0 - Depends on volume - for Data disk
  • For each 1 TB of data 64 GB of RAM is recommended for responsive queries (dashboards and filters). Please keep the ratio between RAM and Data storage size to be 1GB RAM: 16GB Data Disk (recommended) and no more than 1 GB 1GB RAM : 32GB DISK Disk (minimal).

...

titleRAID Support
  • NFS is not supported for the data disk, as the Store relies on file system behavior that NFS does not supply. Data corruption and other problems can occur.
  • Software RAID (such as CentOS built-in RAID

...

  • ) is not supported.

Network Requirements

DPOD requires at least one network interface for accessing DPOD's User Interface and communications with Gateway's Management Interface.

...