- DPOD federated cell member (FCM) should be installed in Non-appliance Mode with High_20dv architecture type, as detailed in the Hardware and Software Requirements.
- Install the following software package (RPM): bc, pciutils, nvme-cli, numactl
- The following software packages (RPMs) are recommended for system maintenance and troubleshooting, but are not required: telnet client, net-tools, iftop, tcpdump
...
Code Block | ||
---|---|---|
| ||
# lsblk NAME MAJ:MIN RM SIZE RO TYPE MOUNTPOINT nvme0n1 259:0 0 2.9T 0 disk └─vg_data2-lv_data 253:6 0 2.9T 0 lvm /data2 nvme1n1 259:5 0 2.9T 0 disk └─vg_data22-lv_data 253:3 0 2.9T 0 lvm /data22 nvme2n1 259:1 0 2.9T 0 disk └─vg_data3-lv_data 253:2 0 2.9T 0 lvm /data3 nvme3n1 259:2 0 2.9T 0 disk └─vg_data33-lv_data 253:5 0 2.9T 0 lvm /data33 nvme4n1 259:4 0 2.9T 0 disk └─vg_data44-lv_data 253:7 0 2.9T 0 lvm /data44 nvme5n1 259:3 0 2.9T 0 disk └─vg_data4-lv_data 253:8 0 2.9T 0 lvm /data4 |
Install NUMA Software
Code Block | ||
---|---|---|
| ||
yum install numactl |
Preparing Local OS Based Firewall
...