Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

  1. DPOD cell manager and federated cell members must be with the same version (minimum version is v1.0.98.05).
  2. DPOD cell manager can be installed in both Appliance Mode or Non-Appliance Mode with Medium Load architecture type, as detailed in the Hardware and Software Requirements. The manager server can be both virtual or physical.
  3. DPOD federated cell member (FCM) should be installed in Non-appliance Mode with High_20dv architecture type, as detailed in the Hardware and Software Requirements.
  4. Each cell component (manager / FCM) should have two network interfaces:
    1. External interface - for DPOD users to access the Web Console and for communication between DPOD and Monitored Gateways.
    2. Internal interface - for internal DPOD components inter-communication (should be a 10Gb Ethernet interface).
  5. Network ports should be opened in the network firewall as detailed below:

...

Cell Manager Installation

Prerequisites

  • DPOD cell manager  manager should be installed in Non-Appliance Mode with Medium Load architecture type, as detailed in the Hardware and Software Requirements. The manager server can be both virtual or physical.

...