User should reboot the server for the new performance optimization should take effect.

Prepare Cell Member for Federation

The cell member is usually "bare metal" server with NVMe disks in order to maximize server throughput.

Each of the Store's logical node (service) will be bound to a specific physical processor , disks and memory (using NUMA technology → Non-uniform memory access ).

The default cell member configuration assume 3 NVMe disks enclosures which will serve 3 Store data nodes.

The following OS mount points should be configured by the user before federating the DPOD installation to "cell member".

Note

We highly recommend the use of LVM (Logical volume Manager) to allow "flexible" storage for future storage needs .


note - colored table cells should be completed by the user based on his specific hardware.


Store Nodemount point pathNVME EnclosureDisk SerialDisk PathCPU No
2/data2



2/data22



3/data3



3/data33



4/data4



4/data44




Examples for Mount Points and Disk Configurations






Cell Member Federation

In order to federate and configure the cell member run the following script on in the cell manager once per cell member.

...