In order to setup a new Remote Collector server you will need to install another new DPOD server based on the prerequisites below. The Node that will contain the Data and the console will be called "Local Node" and the second installation (contains only the Syslog and WS-M agent) will be called "remote collector".

Prerequisites

  1. The DPOD "cell manager " and cell FCM must be with the same version (minimum version is v1.0.9.0 )
  2. DPOD "ce ll manager " can be both "Appliance Mode" or "Non appliance Mode" installation with "medium" architecture type as detailed in the Hardware and Software Requirements. The manager server can be both virtual or physical.
  3. DPOD FCM should be "Non appliance Mode" installation with "High_20dv with High Load" architecture type as detailed in the Hardware and Software Requirements
  4. Each cluster component (manager / FCM ) should have two network interfaces :
    1. External interface - for DPOD users to access UI and for communication between DPOD and Monitored Gateways.
    2. Internal Interface - for internal DPOD components communication (should be 10GB Ethernet interface, for more information see configuring FCM)
  5. Each installation will requires some different ports to be opened in the firewall - see table 1

...

Manager Installation

DPOD cell manager can be both "Appliance Mode" or "Non appliance Mode" installation with "medium" architecture type as detailed in the Hardware and Software Requirements. The manager server can be both virtual or physical.

  • "Appliance Mode" installation procedure

 


Federate Cluster Member Installation

In order to configure the local node and remote collector(s), run the following script in the local node once per remote collector .

...