Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

Info

The following steps apply to all DPOD installations ( Appliance, Non-Appliance, Cell Manager and Cell members)All-in-One, cell manager and cell members).

  1. Some installations might have unused properties in the retention configuration file, which may cause the upgrade to 1.0.16.0 to fail with the following error:

    Code Block
    File /app/hk_retention/MonTier-HK-ESRetention/conf/MonTierHousekeeping.conf contains placeholders
  2. Before applying the upgrade to 1.0.16.0, please execute the following commands:

    Code Block
    sed -i '/elasticsearch\.index\_set\.logical\-tran\-full\.max\_size\=.*/d' /app/hk_retention/MonTier-HK-ESRetention/conf/MonTierHousekeeping.conf
    sed -i '/elasticsearch\.index\_set\.iib\-log\-tran\.max\_size=.*/d' /app/hk_retention/MonTier-HK-ESRetention/conf/MonTierHousekeeping.conf
    sed -i '/elasticsearch\.index\_set\.iib\-stats\-tran\.max\_size=.*/d' /app/hk_retention/MonTier-HK-ESRetention/conf/MonTierHousekeeping.conf

...