DPOD software updates are available from time to time and include enhancements, security updates, component upgrade, bug fixes, etc.

...

The following table describes the upgrade paths between versions:

From
To

1.0.8.0

1.0.8.6

1.0.9.0

1.0.10.0

1.0.10.1

1.0.11.0

1.0.12.0

1.0.13.0

1.0.8.6 1

1.0.8.0 → 1.0.8.6








1.0.9.0

1.0.8.0 → 1.0.8.6
1.0.8.6 → 1.0.9.0

1.0.8.6 → 1.0.9.0







1.0.10.0

1.0.8.0 → 1.0.8.6
1.0.8.6 → 1.0.10.0

1.0.8.6 → 1.0.10.0

1.0.9.0 → 1.0.10.0






1.0.10.1

1.0.8.0 → 1.0.8.6
1.0.8.6 → 1.0.10.1

1.0.8.6 → 1.0.10.1

1.0.9.0 → 1.0.10.1

1.0.10.0 → 1.0.10.1





1.0.11.0

1.0.8.0 → 1.0.8.6
1.0.8.6 → 1.0.11.0

1.0.8.6 → 1.0.11.0

1.0.9.0 → 1.0.11.0

1.0.10.0 → 1.0.11.0

1.0.10.1 → 1.0.11.0




1.0.12.0 2

1.0.8.0 → 1.0.8.6
1.0.8.6 → 1.0.11.0
1.0.11.0 → 1.0.12.0

1.0.8.6 → 1.0.11.0
1.0.11.0 → 1.0.12.0

1.0.9.0 → 1.0.11.0
1.0.11.0 → 1.0.12.0

1.0.10.0 → 1.0.12.0

1.0.10.1 → 1.0.12.0

1.0.11.0 → 1.0.12.0



1.0.13.0

1.0.8.0 → 1.0.8.6
1.0.8.6 → 1.0.11.0
1.0.11.0 → 1.0.13.0

1.0.8.6 → 1.0.11.0
1.0.11.0 → 1.0.13.0

1.0.9.0 → 1.0.11.0
1.0.11.0 → 1.0.13.0

1.0.10.0 → 1.0.13.0

1.0.10.1 → 1.0.13.0

1.0.11.0 → 1.0.13.0

1.0.12.0 → 1.0.13.0


1.0.14.0 3

1.0.8.0 → 1.0.8.6
1.0.8.6 → 1.0.11.0
1.0.11.0 → 1.0.13.0
1.0.13.0 → 1.0.14.0

1.0.8.6 → 1.0.11.0
1.0.11.0 → 1.0.13.0
1.0.13.0 → 1.0.14.0

1.0.9.0 → 1.0.11.0
1.0.11.0 → 1.0.13.0
1.0.13.0 → 1.0.14.0

1.0.10.0 → 1.0.13.0
1.0.13.0 → 1.0.14.0

1.0.10.1 → 1.0.13.0
1.0.13.0 → 1.0.14.0

1.0.11.0 → 1.0.13.0
1.0.13.0 → 1.0.14.0

1.0.12.0 → 1.0.13.0
1.0.13.0 → 1.0.14.0

1.0.13.0 → 1.0.14.0

1 Up to version 1.0.8.6, the fix pack file does not include previous fix packs, so each fix pack should be applied one by one.

2 Version 1.0.12.0 requires at least 1.0.10.0 because of Store engine upgrade and data upgrade issues.

3 Version 1.0.14.0 requires at least 1.0.13.0 because of an architecture change of the Store engine.

Upgrading a Cell Environment

Note: This procedure has changed since 1.0.12.0. In previous versions the process of upgrading a cell environment was different.

To upgrade a cellenvironment:

  1. Make sure the entire cell is up and running. Upgrading is possible only if the cell is healthy.

  2. Upgrade the cell manager.

  3. When the cell manager upgrade is complete,

    the

    the cell manager Web Console will be unavailable. Do not start the services manually on the cell manager unless requested explicitly.

  4. Upgrade all cell members (can be done in parallel).

  5. When the cell members upgrade is complete, start the cell manager services using app-util.sh ("Start All").

Copy the Software Update Files to DPOD Server

  1. DPOD software updates are available through IBM Fix Central. The download consists of two files:

    1. The update file: DPOD-fixpack-<version number>.sfs

    2. The md5 hash calculation of the update file: DPOD-fixpack-<version number>.md5

  2. Copy the update files to the following directory on DPOD server: /installs/update/fix/TODO

  3. If the directory does not exist, execute the following command to create it:

    Code Block
    theme
    languagebashRDark
    mkdir -p /installs/update/fix/TODO

Make Sure there is Enough Disk Space

Inspect the free space of each mount point. You may use the following command:

Code Block
languagebash
themeRDark
df -h

Inspect the size of the internal configuration database. You may use the following command:

Code Block
languagebashthemeRDark
du -sh /app/derby/


Make sure the root ("/") mount point has at least 100 MB free space.

...

Make sure the "/installs" mount point has enough available space using the following table:

Upgrading to

Available Space on "/installs"

1.0.3.X - 1.0.9.X

3 GB + internal configuration database size

1.0.10.0 and above

4 GB + internal configuration database size

If there is not enough available space on the "/installs" mount point, you may free some from the following directories:

Directory

Description

/installs/update/fix/TODO

Remove old DPOD update files (.sfs)

/installs/update/fix/backups

Remove old DPOD backup directories

/installs/APPL-setup
/installs/MonTierInstaller
/installs/rpms

Remove the directories

Follow Special Steps

Some versions require special steps. Make sure to follow them:

Child pages (Children Display)

Install the Software Update

Execute the following commands:

Code Block
languagebash
themeRDark
cd /installs/update/fix/TODO
MonTierUpdateInstaller.sh -u DPOD-fixpack-<version number>.sfs -s DPOD-fixpack-<version number>.md5

For example:
MonTierUpdateInstaller.sh -u DPOD-fixpack-1_0_14_0.sfs -s DPOD-fixpack-1_0_14_0.md5

Please review the upgrade log file if the console displays any error messages.

Note

Do not interrupt the software update process after it has started.

Manual Steps during Software Update

...

Some versions make changes to the installer file itself (MonTierUpdateInstaller.sh). In that case, the following message will be displayed, and the installer should be rerun manually:

Code Block
languagebash
themeRDark
Found new version of the software update installer... updating
Software update installer was updated successfully.

Important !!! Please run the software update installer again.

...

If the upgrade process detects data that should be migrated before applying the upgrade, the following message will be displayed, and the data migration tool should be run manually:

Code Block
languagebash
themeRDark
Some of the existing data needs to be migrated to a newer format or structure.
The data migration tool has been deployed in /installs/data-migration-tool.
Further information can be found in the documentation at: Admin Guide -> Installation and Upgrade -> Upgrade

...

You may edit the configuration file /installs/data-migration-tool/data-migration-tool.conf before running the tool.
The following entries are of interest (other settings should not change unless advised otherwise by IBM support):

  1. duration.limit (default: 999999) - limits the execution time in minutes.
    This option is useful if you want to schedule the tool to run during off-peak time.
    In such a case, you can limit the tool to run for a few hours each time and schedule it to start when off-peak time starts, so performance will not be impacted during peak time hours.

  2. delete.kibana_indices (default: true) - determines whether Kibana indices should be deleted or not.
    true - Delete old Kibana indices - all exiting Kibana dashboards and other settings will be deleted.
    false - Keep Kibana indices and try to migrate them to the new store engine version - however, it is up to you to fix the indices manually according to Kibana's documentation.

Running the Data Migration Tool

  1. Make sure DPOD is up and running. The data migration tool is designed to work while DPOD is up and running, so users may sign in to DPOD and use it while the data migration tool is upgrading the data in the background.

  2. Since the tool is a long-running process, it is recommended to run it in a "no hang-up" mode, which will cause the process to continue running even after the SSH session is closed. In this mode, the console output is written to nohup.log file in the local directory.

     Use

     Use the following command to run the tool and inspect the console output:

    Code Block
    languagebashthemeRDark
    nohup /installs/data-migration-tool/data-migration-tool.sh &
    tail -f nohup.out
  3. The data migration process may take anywhere between a few minutes and a few days, depending on the amount of data, the server load and the server hardware.

     A

     A rough estimation of the time left will be presented while the process is running.

  4. Please review the data migration tool log file (/installs/logs/store_data_migration.log) if the console displays any error message.

Interrupting the Data Migration Tool

...

While this is usually not an issue, note that on some cases it may cause complications, for example:

  1. The user wants the tool to run during a nightly maintenance window, between 2-4 AM.

  2. The tool is scheduled using cron to 2 AM and the duration.limit setting is set to 120 minutes.

  3. For this specific user, depending on its hardware and data sizes, processing of each index takes about 3 hours.

  4. Since the tool is interrupted after 2 hours, on the next night, the tool will try to migrate the same index again and will never advance to the next index.