A Firmware Upgrade Activity defines which devices should be upgraded, to which versions, the pre/post actions and the error policy to use.
...
Before DPOD can use a firmware image, it needs to be uploaded into the DPOD's path that was defined in the System Parameter "Firmware Upgrade - Repository Path".
You can use SCP/WinSCP or any other file transfer program to upload the file.
Add Activity Page
Attribute | Is Mandatory? | Description | ||
---|---|---|---|---|
Device (or Pattern) | Yes | The device(s) to upgrade. Enter a specific device, pattern with asterisk or a list of devices or patterns. See Using Patterns for Device and Domain Names in the Maintenance Concepts page. | ||
Don't check version downgrade | No | By default, firmware downgrade is not supported (for example, from 7.5.1.5 back to 7.5.1.3). | ||
Allow Features Incompatibility | No | Allows to upload a firmware image file that is missing features that are found on the device (Tibco-EMS and DCO-Oracle). | ||
Pre-Action Script | No | A user defined script to run before the task is executed. | ||
Pre-Action Quiesce | No | Should the device(s) be quiesced before it is restarted.
| ||
Pre-Action Restart | No | Should the device(s) be restarted before the upgrade starts.
| ||
Seconds to wait after restart | Yes (if restart requested) | How long (in seconds) to wait after restart and before issuing the quiesce request and upgrading the firmware. This parameter is used for situations where the monitored device does not enter "ready" state immediately after device restate. | ||
Pre-Action Quiesce | Yes | Always checked, this option cannot be changed. The device will be quiesced before the upgrade starts. The timeout value that is passed to the quiesce SOMA is controlled by a system parameter (see Maintenance Configurable Parameters for more information) | ||
Image File | Yes | The firmware image file, only scrypt3, scrypt4 and tar.gz types are supported Click the Three dots button to open the file selection window, the window will show all image files that were found in the Repository path (see "Firmware Upgrade - Repository Path") If a new file was just uploaded, close and re-open the window to refresh the list. | ||
Upgrade timeout in seconds | Yes | How long to wait before DPOD will mark the upgrade execution as failed. For example, if DPOD did not receive any response from the upgraded device after 30 minutes, it will mark the execution as failed, so a syslog/email will be sent. | ||
Post-Action Unquiesce | No | Always checked, this option cannot be changed. | ||
Post-Action Script | No | A user defined script to run after the task is executed. | ||
Error Policy | Yes | Select how this activity handles errors. | ||
Accept License ChechboxCheckbox | Yes | Accept IBM's license is needed before firmware upgrade. |
...