Federated architecture best fits customers that execute high load (thousands of transactions per secondssecond) in their gateways, where the vast majority of the transactions is executed on-premise. 

The cell environment implements the federated architecture by distributing DPOD's Store and DPOD's processing (using DPOD's agents) across different federated servers.

...

  1. DPOD cell manager and federated cell members must be with the same version (minimum version is v1.0.8.5).
  2. DPOD cell manager can be installed in both Appliance Mode or Non-Appliance Mode with Medium Load architecture type, as detailed in the Hardware and Software Requirements. The manager server can be both virtual or physical.
  3. Physical DPOD federated cell member (FCM) must be installed in Non-appliance Mode with High_20dv architecture type, as detailed in the Hardware and Software Requirements.
  4. Virtual DPOD federated cell member (FCM) must be installed in Non-appliance Mode with Medium architecture type or higher, as detailed in the Hardware and Software Requirements and in Virtual Cell Environment Installation.
  5. All DPOD federated cell member (FCM) must have the excatly exactly the same resources such CPUs , Memory , disk type and storage capacity.
  6. Each cell component (manager / FCM) should have two network interfaces:
    1. External interface - for DPOD users to access the Web Console (on the cell manager) and for communication between DPOD and Monitored Gateways (on both the cell manager and the members).
    2. Internal interface - for internal DPOD components inter-communication (should be a 10Gb Ethernet interface).
  7. Network ports should be opened in the network firewall as detailed below:

...

The following section describes the installation process of a single Federated Cell Member (FCM). User should repeat the procedure for every FCM installation.

Note
Important !!  The initial installation (until the federation process is executed) of both Cell Manager and Cell Members is a standard All-In-One standalone DPOD installation .
In order for the initial installation to complete successful  all per-requisites for DPOD installation should be met as described on Hardware and Software Requirements  and Prepare Pre-Installed Operating System (including the 3 disk drives)

Prerequisites

  • DPOD federated cell member (FCM) should be installed in Non-appliance Mode with High_20dv architecture type, as detailed in the Hardware and Software Requirements.
  • Install the following software package (RPM): bc
  • The following software packages (RPMs) are recommended for system maintenance and troubleshooting, but are not required: telnet client, net-tools, iftop, tcpdump, pciutils, nvme-cli

...