- DPOD cell manager and federated cell members must be with the same version (minimum version is v1.0.8.5).
- DPOD cell manager can be installed in both Appliance Mode or Non-Appliance Mode with Medium Load architecture type, as detailed in the Hardware and Software Requirements. The manager server can be both virtual or physical.
- Physical DPOD federated cell member (FCM) must be installed in Non-appliance Mode with High_20dv architecture type, as detailed in the Hardware and Software Requirements.
- Virtual DPOD federated cell member (FCM) must be installed in Non-appliance Mode with Medium architecture type or higher, as detailed in the Hardware and Software Requirements and in Virtual Cell Environment Installation.
- All DPOD federated cell member (FCM) must have the excatly the same resources such CPUs , Memory , disk type and storage capacity.
- Each cell component (manager / FCM) should have two network interfaces:
- External interface - for DPOD users to access the Web Console (on the cell manager) and for communication between DPOD and Monitored Gateways (on the cell members).
- Internal interface - for internal DPOD components inter-communication (should be a 10Gb Ethernet interface).
- Network ports should be opened in the network firewall as detailed below:
...