Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

  1. DPOD cell manager and federated cell members must be with the same version (minimum version is v1.0.8.5).
  2. DPOD cell manager can be installed in both Appliance Mode or Non-Appliance Mode with Medium Load architecture type, as detailed in the Hardware and Software Requirements. The manager server can be both virtual or physical.
  3. Physical DPOD federated cell member (FCM) must be installed in Non-appliance Mode with High_20dv architecture type, as detailed in the Hardware and Software Requirements.
  4. Virtual DPOD federated cell member (FCM) must be installed in Non-appliance Mode with Medium architecture type or higher, as detailed in the Hardware and Software Requirements and in Virtual Cell Environment Installation.
  5. All DPOD federated cell member (FCM) must have the excatly the same resources such CPUs , Memory , disk type and storage capacity.
  6. Each cell component (manager / FCM) should have two network interfaces:
    1. External interface - for DPOD users to access the Web Console (on the cell manager) and for communication between DPOD and Monitored Gateways (on both the cell manager and the members).
    2. Internal interface - for internal DPOD components inter-communication (should be a 10Gb Ethernet interface).
  7. Network ports should be opened in the network firewall as detailed below:

...